Hi Everyone. Well, after 15 years the RV-Dreams Community Forum is coming to an end. Since it began in August 2005, we've had 58 Million page views, 124,000 posts, and we've spent about $15,000 to keep this valuable resource for RVers free and open. But since we are now off the road and have settled down for the next chapter of our lives, we are taking the Forum down effective June 30, 2021. It has been a tough decision, but it is now time.


We want to thank all of our members for their participation and input over the years, and we want to especially thank those that have acted as Moderators for us during our amazing journey living and traveling in our RV and growing the RV-Dreams Family. We will be forever proud to have been founders of this Forum and to have been supported by such a wonderful community. Thank you all!!

Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: Running two air conditioners


RV-Dreams Family Member

Status: Offline
Posts: 41
Date:
Running two air conditioners


I have a Cardinal 2006 36TS. It has two air conditioners. I am hooked up to 50amp service. Whenever i attempt to run both air conditioners, it trips a breaker. Is this normal, or should i be able to run both at the same time?
Thanks
Al Viscardi

__________________
Al Viscardi
2006 Cardinal 36TS, 2005 Dodge 2500
www.mytripjournal.com/freeatlast


RV-Dreams Family Member

Status: Offline
Posts: 1438
Date:

You should be able to run both air conditioners without problem. I bleieve they draw about 15 amps each.
You might have a problem if you are using other high amperage items at the same time, like hair dryers, microwave, toaster, washer or dryer.

Good luck,
Fred

__________________
Fred Wishnie

Full time since Feb 06 in Carriage Cameo 35KS3 and Ford F350


“If all you ever do is all you’ve ever done, then all you’ll ever get is all you ever got.”


RV-Dreams Family Member

Status: Offline
Posts: 3722
Date:

Can you run both air conditioners individually without tripping the breaker? Just troubleshooting that the second air conditioner has a problem. In a normally wired 50AMP RV there are two 50AMP 110volt power legs and each leg has an air conditioner. Normally one leg has the fridge, electric hot water heater, washer/dryer (if included) and the "primary" air conditioner wired to it and the second leg is the plugs, microwave and "secondary" air conditioner.
Also does this happen at multiple campgrounds or only one? Sometimes you are dealing with a campground problem and not your own problem. Maybe it is really not 50AMP service but just looks like it is.
We run both air conditioners all the time on 50AMP. As Fred says they take about 15 amps each.
On 30AMP we normally run the front one but if we just want to run the rear one only we have to set the front one to some high number like 99 degrees since they share a thermostat and the thermostat won't let the rear one run without the front one turned on.

-- Edited by bjoyce at 20:18, 2007-05-27

__________________

Bill Joyce,
40' 2004 Dutch Star DP towing an AWD 2020 Ford Escape Hybrid
Journal at http://www.sacnoth.com
Full-timing since July 2003



RV-Dreams Family Member

Status: Offline
Posts: 319
Date:

Hi Al:

Everything stated so far is correct.  There should be no problem running both air conditioners with a 50 amp feed.  Many things could be affecting this.  There could be a problem with one or both air conditioners, but if you have used them successfully other palces I suspect the problem is with the 50 amp breaker itself or the plug is worn or burned.  Breakers get old and sometimes cannot carry their rated current any longer.  If the receptacle is old, worn or broken there is a possibility that the contact with you plug is poor causing arcing between the plugs terminals and the receptacle.  If there is arcing you can easily tell by pulling your plug and looking to see if the pins are burned.  A third possibility is that the transformer and/or wiring to the outlet in the park is not capable of supplying the amperage stated on the breakers without a serious voltage drop.  This condition is dangerous to your air conditioners and other electrical appliances in your RV.  You would be well served to get a volt meter and watch the voltage as the air conditioners start up.  If the voltage drops below 90 to 95 volts damage could very well result.  I personally will not use my air conditioners if the voltage drops below 110 for very long.  It puts a real strain on starting capacitors in your air conditioners.

I hope this helps. 

__________________
Full timing since 1/1/2005
American Tradition & Jeep Wrangler
www.howethsjournal.blogspot.com


RV-Dreams Family Member

Status: Offline
Posts: 175
Date:

Do you trip a breaker in the coach or at the campground service pole? I have been to a couple of campgrounds that have single phase service that trips easily... Don



__________________
www.rvdaydreams.blogspot.com
2002 29' Prowler TT pushing a 2002 GMC 2500HD "BIG RED"
Counting the days until we fulltime but not forgetting to enjoy everyday as a gift from God.


RV-Dreams Family Member

Status: Offline
Posts: 1043
Date:

Bill mentioned something that we all forget sometimes. Hot Water Heater. It is the hidden force that we over look. Sometimes if your in a park that is marginal on the Ampers you might have to go over to gas to get by with the two airs. This has happened to us.

Joe and Sherri

__________________

 

Joe Sherri and Kris living in a Open Range Lite 308BHS. 2500 Dodge Ram Diesel  http://speedysgreatadventure.blogspot.com/