Hi Everyone. Well, after 15 years the RV-Dreams Community Forum is coming to an end. Since it began in August 2005, we've had 58 Million page views, 124,000 posts, and we've spent about $15,000 to keep this valuable resource for RVers free and open. But since we are now off the road and have settled down for the next chapter of our lives, we are taking the Forum down effective June 30, 2021. It has been a tough decision, but it is now time.
We want to thank all of our members for their participation and input over the years, and we want to especially thank those that have acted as Moderators for us during our amazing journey living and traveling in our RV and growing the RV-Dreams Family. We will be forever proud to have been founders of this Forum and to have been supported by such a wonderful community. Thank you all!!
I have an Onan 5500 propane generator installed in the coach. It's new, like the 5th wheel, and has about 25 hours on it. I've been running it for about 10-15 minutes every few months. It always starts promptly and runs great. Does that sound like the right way to ensure it stays healthy?
-- Edited by RonC on Friday 31st of March 2017 03:49:55 PM
__________________
Ron and Janice
2016 Ford F350, King Ranch, DRW, 4x4, CC, 6.7 PS Diesel, remote control air lift system
2017 Durango Gold 381REF, Lambright furniture, MCD shades, morRYDE IS, 8K Disc brakes, GY G114 LR H Tires, 27,320 lbs CGVW
Maybe we are a bit overkill but we try to exercise ours at least once a month (sometimes when winterized can be up to 2 months max) and try to run it for 40 mins to an hour.
__________________
Breathtaking Alberta. Her Mountains Draw You But Her People Bring You Back
Winnebago TT 2101DS & 2020 Silverado LTZ Z71. 300 watts WindyNation solar w/MPPT, 2 Trojan T-125s. TALL flag pole. Prefer USFS, COE, BLM, USF&WS, NPS, TVA, state/county camps. 14 year Army vet-11B40 then 11A - old MOS 1542 & 1560.
I have an Onan 5500 propane generator installed in the coach. It's new, like the 5th wheel, and has about 25 hours on it. I've been running it for about 10-15 minutes every few months. It always starts promptly and runs great. Does that sound like the right way to ensure it stays healthy?
-- Edited by RonC on Friday 31st of March 2017 03:49:55 PM
Speaking for the LP unit like you have Ron, not gas: LP is VERY forgiving unlike the gas units when allowed to sit. They "should" be run once a month. I get behind on ours which is now 10 years old and always starts - its LP. When you do run it run it under a load. Like run both AC units to give it a nice 15 amp load on each side and I'd run it for 20 minutes or so to get it hot. The manual does recommend exercising it. Let it idle to cool down after running under load. All this has worked well for us.
You have, IMO for a large unit, a great generator choice for a 5er. The LP 5500 we have we actually moved from our previous trailer as it was in such good shape and had relatively low hours. Now, as I said, 10 years old and works super. Be sure and change the oil / filter each year per the manual regardless of hours in service.
Just for info: A nice thing about the LP's is that altitude has far less impact on them. There is actually no leaning adjustment on the LP units. We've run ours at 9,000+ feet without issue.
Years ago a friend had a nice chat with an Onan engineer on the subject. The Onan engineer says they put monthly exercising in all their manuals because that is what they recommend for gas generators. Practically he recommended every 3 months for LP generators and 6 months for diesel, but those could slip if needed. They also want the generators to run under load, which means about 50% of the wattage, for 30 minutes. This gets everything to operating temperatures and cleans up any deposits. Idling for 30 minutes is not good, it is actually hard on the engine. I have not met anyone that had trouble with their gas generator or gas engine after sitting still for 3 months in winter and many go longer. Going longer they might have a hard start, just like your lawn mower in spring, but then will run.
__________________
Bill Joyce, 40' 2004 Dutch Star DP towing an AWD 2020 Ford Escape Hybrid Journal at http://www.sacnoth.com Full-timing since July 2003