Hi Everyone. Well, after 15 years the RV-Dreams Community Forum is coming to an end. Since it began in August 2005, we've had 58 Million page views, 124,000 posts, and we've spent about $15,000 to keep this valuable resource for RVers free and open. But since we are now off the road and have settled down for the next chapter of our lives, we are taking the Forum down effective June 30, 2021. It has been a tough decision, but it is now time.
We want to thank all of our members for their participation and input over the years, and we want to especially thank those that have acted as Moderators for us during our amazing journey living and traveling in our RV and growing the RV-Dreams Family. We will be forever proud to have been founders of this Forum and to have been supported by such a wonderful community. Thank you all!!
I learned something new today over on another forum. A participant there asked the question about something between the switches for electric and gas with regards to the hot water heater. He had seen the letters "DSI" with a red indicator light between that and the letters "FLT." So, I went to look at ours and we have similar but instead of "FLT," ours had the word "fault."
So, with the opportunity to learn something new, I went and used my "Bing-fu" skills to find out. DSI stands for "Direct Spark Ignitor." I also found an explanation of the DSI Fault at another forum. A participant there gave this description:
"OK that means your hot water heater failed to start. It tried 3 times and locked out. Direct Spark Ignitor fault (flt). You probably have air in the line and it needs to be flushed out. I usually just run my stove top on 3 burners for a minute to bleed the air out. Just turn the hot water heater off for a minute or so and it should try again 3 more times till it lights. If not its gas side is broke. Electric side should still work."
So, since I learned something new, I thought I'd pass that same information off to others, some of whom haven't even RV'ed yet.
Terry
__________________
Terry and Jo
2010 Mobile Suites 38TKSB3 2008 Ford F450 2019 Ford Expedition Max as Tag-along or Scout
I'm having some issues with my six gallon DSI gas only Atwood water heater. I searched "DSI FLT" and was rewarded with Terry's post from a few years ago and thought this would be good place to post my question.
When I first turn on my water heater from the monitor panel, it fires up right away and heats the water to what I assume is the proper temperature then shuts down. (When I get a moment I'll get a thermometer and check the temperature) But as hot water is used, or the temperature just drifts down, the heater does not come back on but I see the DSI FLT (fault) LED come on. If I turn off the water heater switch at the monitor panel then turn it back on, the water heater fires back up, heats the water but will not cycle back on when needed. The manual says this indicates a problem with the igniter but the igniter never fails to ignite when I first turn on the water heater or when I switch it off then back on.
This RV is just over a year old and I first noticed this problem about a month ago.
Has anyone experienced this or have a suggestion on what to check?
Thanks,
Steve
__________________
2017 Starcraft 26BHS Autumn Ridge TT, 2019 Chevrolet 3500 SRW Duramax 6.6 4WD TV
Plan to retire/full-time in 2021. Favorite place to camp; Texas State Parks.