Hi Everyone. Well, after 15 years the RV-Dreams Community Forum is coming to an end. Since it began in August 2005, we've had 58 Million page views, 124,000 posts, and we've spent about $15,000 to keep this valuable resource for RVers free and open. But since we are now off the road and have settled down for the next chapter of our lives, we are taking the Forum down effective June 30, 2021. It has been a tough decision, but it is now time.


We want to thank all of our members for their participation and input over the years, and we want to especially thank those that have acted as Moderators for us during our amazing journey living and traveling in our RV and growing the RV-Dreams Family. We will be forever proud to have been founders of this Forum and to have been supported by such a wonderful community. Thank you all!!

Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: Electric plug that combines 30 and 20 amp


RV-Dreams Family Member

Status: Offline
Posts: 164
Date:
Electric plug that combines 30 and 20 amp


I did a search, but couldn't find if this topic has been discussed. 

We're wondering if anyone has purchased the electrical plug that has a plug for the 30 amp and 20 amp outlets and then is supposed to give you 50 amps of power.   Basically, it is supposed to combine the power from the two different outlets.  We've seen it advertised, but are wondering how well it works.

Thanks for any information you might be able to share aww



__________________

Life's Journey is not to arrive at the grave safely in a well preserved body, but rather to skid in sideways,
totally worn out, shouting "Wow...What a Ride!
2012 GMC 2500HD Diesel
2014 Jayco Pinnacle 36REQS
http://rvkhroniclesofkevelyn.blogspot.com/



RV-Dreams Family Member

Status: Offline
Posts: 292
Date:

I know a few people that have them but I don't own one. Looks like a good idea but it may interfere with your power management system/surge protector.

Click Here for Cheater Box>>http://www.pplmotorhomes.com/parts/rv-power-cords/rv-cheater-box.htm




__________________

Mark & Nancy
2004 F-250 XLT 6.0 Diesel
2001 Sunnybrook 2708 TT



RV-Dreams Family Member

Status: Offline
Posts: 5399
Date:

Well, I'm now going to have to go looking.  It seems that I asked something the same as you some time back, but I couldn't seem to find it.

For some reason, I remember that there might be an issue with using them if the 20amp socket at the power pole was one of the ground fault interrupter types.  If I find what I'm thinking I asked, I'll provide a link.

Terry

Edit:  OK.  It wasn't me with the question.  Since I am at work and using the Firefox browser, it won't let me post an active link.  Use the search feature and use "30 Amp to 50" as your search term.


-- Edited by Terry and Jo on Wednesday 12th of January 2011 02:32:48 PM

__________________

Terry and Jo

2010 Mobile Suites 38TKSB3
2008 Ford F450
2019 Ford Expedition Max as Tag-along or Scout

Our photos on Smugmug



RV-Dreams Family Member

Status: Offline
Posts: 259
Date:

I am no electrician but this sounds like trying to squeeze a square peg into a round hole. There is a chance it can be done but not without damaging something.

__________________


RV-Dreams Family Member

Status: Offline
Posts: 1192
Date:

An electrician I'm not...I struggle to understand RV power systems. But I can tell you that 50 amp RV service is actually 2 legs @ 50 amps each...total 100 amps.

It would help to know what problem you are trying to solve as there may be better solutions.

__________________

2018 Thor Windsport 35M -- 2018 Camry Toad

-- USAF Retired -- Full-timing since December 2007 - Part-Timing since July 2011
VisitedStatesMap.jpg
http://http://travelingrvwx.com/



RV-Dreams Family Member

Status: Offline
Posts: 3722
Date:

Mine comes with two 30AMP plugs and a 30 to 20AMP adapter. While it doesn't give you the full 100AMPs of a real 50AMP plug, which is really 50AMPs of 220, it will let you run both air conditioners plus a bit more. We used ours at the house and at the sister-in-laws house, which had two 30AMP plugs, and at a rally where we could use two 20AMP circuits. I don't remember if we were ever allowed to use it at a campground, but Thousand Trails Las Vegas lets you use one in summer for an extra $5/day since the campground is not busy.

__________________

Bill Joyce,
40' 2004 Dutch Star DP towing an AWD 2020 Ford Escape Hybrid
Journal at http://www.sacnoth.com
Full-timing since July 2003



RV-Dreams Family Member

Status: Offline
Posts: 53
Date:

Yes, Terry is correct. If you try and use it with a 20 A GFI outlet, the GFI will trip and shut off the 20 A outlet, leaving you with only the 30A.  Most commercial campgrounds now have the 20A outlet as a GFI outlet. But if you're not plugging it into a GFI outlet you'll be fine. I built one to pull 20A from two different circuits in my garage so I could get to 40A. I also use it when visiting friends and do the same thing.

Good luck,

Lance

__________________


RV-Dreams Family Member

Status: Offline
Posts: 642
Date:

Many campgrounds post signs that use of the "stealer Plugs" is prohibited. Haven't seen that in state parks.

__________________
Ken and Fran 2006 Sunnybrook F250 SD CC PSD


RV-Dreams Family Member

Status: Offline
Posts: 2074
Date:

The comments about GFI outlets and use of these “cheater plugs” are correct. They can't work with a GFI outlet. Also correct, when they do work, about them only giving you only 50 amps of 120 volts, not the two legs of 50 amps (100 amp total) that you would expect.  (I never liked the way this has always been stated as it is very confusing to people who have no background in electrical service.)

But here is the bigger deal:  These sort of worked “back when” the electrical codes did not require a GFI (ground fault interrupt) breaker on all outside (and some inside) 120 volt 20 amp outlets. (The GFI is not required on a 30 amp plug.)  Now with that NEC code in place for a lot of years the reality is the GFI breaker will always trip and the 120 volt 20 amp feed will be turned off.  That’s a long discussion as to why.  Let’s just say, the cheater cord doesn’t work with a GFI outlet.

Bill J’s comments are correct as to what they give you if they work, but I wouldn’t count on them working except where there is no GFI.  It’s the GFI breaker, not the 20 amp or 30 amp outlet plug as such.  For what it is worth, I don’t carry one but that doesn’t mean you shouldn’t if you care to.

Safe travels

Bill



-- Edited by Bill and Linda on Friday 14th of January 2011 11:18:43 AM